Now working on Line 2Column 5, line 2: The flow rate is the sum of that from Koffee Au Noir and Elsie’s Dairy Kreamer: ¢  0,0202 m3 /s +​14,5  L/s/1000  L/m3 =0,0347 ¢  Note: Because there are no additional flows for the remainder of the lateral, this flow rate is repeated in the remaining lines of this column.Column 6, line 2: Because 0.0347 m3/s is greater than the flowing full capacity of the 250 mm diameter pipe at the minimum slope, use Table 1 and select a 300 mm diameter pipe to carry the flow.

Language: english
PDF pages: 34, PDF size: 2.46 MB
Report
Lampiran Contoh Hasil Perhitungan Program
lampiran contoh hasil perhitungan program
. gelombang fungsi trigonometri. Berikut adalah nilai y0 hingga y31 dari contoh sampel ini : y0 y1 y2 y3 y4 y5 y6 y7.

Language: english
PDF pages: 38, PDF size: 0.07 MB
Report
Asas: Ujian Beban Maintaned Load Test Contoh Pengiraan
asas: ujian beban maintaned load test contoh pengiraan
2nd Cycle – up to Twice Working Load 25% of working load for each increment Up to 2 x working load (8 increments) Maintained minimum 2 hours at each increment ATAU rate of settlement 0.05mm in 15 minutes is reached. Maintained 24 hours at 2 times Working Load. Reading is taken at 15 minutes interval Reading of pile settlement is taken before and after increment Unloading at 4 equal stages @ 1 hour interval. Wait 1 hour after zero load to record residual settlement Plot load/time graph and load settlement .

Language: english
PDF pages: 19, PDF size: 3.73 MB
Report
Asas: Ujian Beban 1. Maintaned Load Test I. Contoh Pengiraan
asas: ujian beban 1. maintaned load test i. contoh pengiraan
2nd Cycle – up to Twice Working Load 25% of working load for each increment Up to 2 x working load (8 increments) Maintained minimum 2 hours at each increment ATAU rate of settlement 0.05mm in 15 minutes is reached. Maintained 24 hours at 2 times Working Load. Reading is taken at 15 minutes interval Reading of pile settlement is taken before and after increment Unloading at 4 equal stages @ 1 hour interval. Wait 1 hour after zero load to record residual settlement Plot load/time graph and load settlement .