Merlin Gerin Schneider Error
merlin gerin schneider error
Protection devices continuously monitor the electrical status of system units and cause them to be de-energized (e.g. tripped by a circuit breaker) when they are the site of a disturbance: short-circuit, insulation fault. The objectives are: to contribute to protecting people against electrical hazards, to prevent equipment damage (the power produced by a three-phase short-circuit on a MV busbar can melt up to 50 kg of copper within 1 second, the temperature at the centre of the arc can exceed 10,000C), .

Language: english
PDF pages: 60, PDF size: 0.53 MB
Report
Merlin Gerin Technical Guide Schneider Electric
merlin gerin technical guide schneider electric
The voltage, the rated current and the rated frequency are often known or can easily be defined, but how can we calculate the short-circuit power or current at a given point in an installation? Knowing the short-circuit power of the network allows us to choose the various parts of a switchboard which must withstand significant temperature rises and electrodynamic constraints. Knowing the voltage (kV) will allow us to define the dielectric withstand of the components. E.g.: circuit breakers, insulators, CT.

Language: english
PDF pages: 80, PDF size: 0.87 MB
Report
Merlin Gerin Bardin Clip Fault Passage Schneider Electric
merlin gerin bardin clip fault passage schneider electric
FLITE11X is a single-phase Fault Passage Indicator for Overhead Line, and should be used in group of 3 units at each location in order to allow for the detection of all possible faults configurations. Like other FPIs, it must be installed at well-defined strategic locations along the overhead line such as : start of a spur tab or bifurcation point and sectionalizers. It mounts directly on the live MV conductor thanks to its specially-designed spring operated clamp and by means of an isolated hot-stick .

Language: english
PDF pages: 16, PDF size: 0.53 MB
Report
0evolis Merlin Gerin 024 Kv - Schneider Electric Belgique
0evolis merlin gerin 024 kv - schneider electric belgique
Language: english
PDF pages: 36, PDF size: 8.08 MB
Report
Function Description Schneider Electric Merlin Gerin Square
function description schneider electric merlin gerin square
b Vacuum interrupters basically have two electrical contacts, one fixed and the other mobile, and a sealed enclosure. The latter enables a high level of vacuum to be maintained inside the interrupter (less than 10-2 Pa) to provide insulation between the open contacts. b The dielectric strength of the vacuum allows the contact-to-contact distance to be reduced. This short distance together with the low opening speed allow the use of a low energy control mechanism. A metal bellows provides the link between .