Oki Tv Service Manual

Sponsored link: Download Oki Tv Service Manual
On this page you can read or download Oki Tv Service Manual in PDF format. We also recommend you to learn related results, that can be interesting for you. If you didn't find any matches, try to search the book, using another keywords.
Lcd Tv Service Manual
lcd tv service manual
With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1MΩ and 5.2MΩ. When the exposed metal has no return path to the chassis .

Language: english
PDF pages: 81, PDF size: 11.12 MB
Report
Lcd Tv Service Manual
lcd tv service manual
With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1MΩ and 5.2MΩ. When the exposed metal has no return path to the chassis .

Language: english
PDF pages: 81, PDF size: 11.12 MB
Report
Lcd Tv Service Manual
lcd tv service manual
Do not use a line Isolation Transformer during this check. Connect 1.5 K / 10 watt resistor in parallel with a 0.15 uF capacitor between a known good earth ground (Water Pipe, Conduit, etc.) and the exposed metallic parts. Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more sensitivity. Reverse plug the AC cord into the AC outlet and repeat AC voltage measurements for each exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS which is corresponds .

Language: english
PDF pages: 77, PDF size: 4.51 MB
Report
Lcd Tv Service Manual
lcd tv service manual
Do not use a line Isolation Transformer during this check. Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor between a known good earth ground (Water Pipe, Conduit, etc.) and the exposed metallic parts. Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more sensitivity. Reverse plug the AC cord into the AC outlet and repeat AC voltage measurements for each exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS which is corresponds to 0..

Language: english
PDF pages: 74, PDF size: 3.88 MB
Report
Color Tv Service Manual
color tv service manual
With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1MΩ and 5.2MΩ. When the exposed metal has no return path to the chassis .

Language: english
PDF pages: 73, PDF size: 8.91 MB
Report
1   2   3   4   5   6   7   8   9   10   Next page →
English ▼
Home Copyright Information Privacy Policy Contact us

PDFSB.NET | All Rights Reserved
This project is a PDF search engine and do not store, hold or retain any files.